Which of the following standpipe systems is exclusively intended to be used by trained fire fighters?

Which standpipe system is used by fire department members trained in the use of large hose streams?

Class III standpipe system
Class III – A Class III standpipe system shall provide 1 1/2 inch hose stations to supply water for use by trained person- nel and a 2 1/2 inch hose connection to supply a larger volume of water for use by fire departments and those trained in heavy fire streams.

Which standpipe system is primarily for use by fire suppression personnel trained in handling large Hoselines?

Class 1: Standpipe systems are primarily for use by a fire-suppression personnel trained in handling large hoselines. Class 2: the system that's primarily designed for use by building occupants who are trained in its use for or by fire personnel.

Which class of standpipe system is designed for use by only the fire department?

There are three classes of standpipes found within buildings: Class 1, 2, and 3. A Class 1 standpipe is designed for firefighting personnel only as it is equipped with just a 2½-inch outlet (see photo 1).

Which class of standpipe system is intended?

Class II standpipes are intended to be used by the occupants of the building, like fire extinguishers, and are equipped with a valve and 1.5-inch hose connection at each location.

What type of standpipe system is used by firefighters?

Manual Dry Standpipe system are exclusively for fire department use and require a fire department pumper to supply the need pressure and water supply through a fire department connection.

What is fire standpipe system?

Standpipe systems are a series of pipes which connect a water supply to hose connections, basically an extension of the fire hydrant system. They are designed to provide a pre-piped water system for building occupants or the fire department.

What is a standpipe fire suppression system?

Standpipe systems are a series of pipes which connect a water supply to hose connections, basically an extension of the fire hydrant system. They are designed to provide a pre-piped water system for building occupants or the fire department.

Why are Type II standpipe systems so undesirable for firefighters?

Why are Type II standpipe systems so undesirable for firefighters? Hazards: Standpipe systems may be poorly maintained, vandalized, improperly designed and incorrectly installed.

How does a fire standpipe system work?

Within the context of a building or bridge, a standpipe serves the same purpose as a fire hydrant. … The standpipe is then "sunk" into the hydrant, and the hose is connected to the exposed ends of the standpipe. The bar is then combined with the key, and is used to turn the hydrant on and off.

Which type of standpipe is the most desirable?

design must allow class 1 and 2 systems to be used simultaneously. contains water at all times. the water supply is capable of meeting the system demand automatically. a wet standpipe with an automatic water supply is more desirable because water is constantly available a the hose station.

Which class standpipe system provides 2 and 1/2 inch hose connections?

Class I
Class I – A Class I standpipe system shall provide a 2 1/2 inch hose connection for use primarily by trained personnel or by the fire department during initial response.